Roll over image to zoom in

Need help with your application? Contact us for expert advice on AMETEK Drexelbrook level instrumentation.

ABLE are AMETEK Drexelbrook’s Exclusive Representative for Sales and Service in the UK and Ireland and can assist you and your customers in the following areas:

  • Application expertise across the full AMETEK Drexelbrook product range
  • Our factory trained engineers offer after‑sales support, service and maintenance (contracts available)
  • In‑depth AMETEK Drexelbrook product training, either in person or via video call

Further to the above, ABLE can offer customised solutions based on your individual requirements. Email us now at info@247able.com

AMETEK Drexelbrook Safety IntelliPoint Loop / Line Powered Level Switch

Auto‑calibrating SIL2 RF Level Switch with Coating Immunity & Self‑Diagnostics

ABLE Instruments are AMETEK Drexelbrook’s Exclusive Representative for Sales and Service in the UK and Ireland, including the Safety IntelliPoint Loop & Line Powered Level Switch. The Safety IntelliPoint Level Switch is designed for safety-critical point level detection with functional safety performance up to SIL2. It uses RF admittance technology with No‑Cal™ auto-calibration, Cote‑Shield™ coating immunity and an AutoVerify™ continuous self-test system. A Manual Certify™ feature allows users to validate system integrity without removing the sensor. Offering both loop-powered (4–20 mA) and line-powered options, it suits versatile installations and ensures reliable output in hazardous applications. Approved for use in SIL-level safety instrumented systems, it is ideal for high-integrity overfill protection, interface detection in oil and slurries, or level control in critical process vessels.

Key Features:

  • SIL2 functional safety certified: Designed for use in safety-critical systems to IEC61508 standards
  • No calibration required: Auto‑calibrates on power-up (No‑Cal™)
  • Cote‑Shield immunity: Ignored coatings or residue prevent false alarms
  • Continuous diagnostics: AutoVerify™ self-test and manual Certify™ verify electronics and sensing element
  • Dual power options: Loop‑powered 13‑30 VDC or universal line power 85‑250VAC / 21‑100 VDC
  • SPDT output flexibility: Dry‑contact relay and/or current output options available
  • RF admittance technology: Reliable switching with no moving parts
  • Hazardous area compliance: FM, FMc, ATEX, IECEx (Class I Div 1 / Zone 0), dual-compartment housing for safety isolation

Have a particular project in mind? We’d welcome a call on +44 (0) 1189 169 420

Safety IntelliPoint Specifications:

Technology
RF Admittance with Cote‑Shield coating immunity
Calibration
None – Auto‑calibrates on power-up (No‑Cal™)
Safety Certification
SIL2 (SIL3 with redundant switch), FMEDA & IEC61508‑2 certified
Diagnostic Features
AutoVerify™ continuous self-test; Manual Certify™ for full-system verification
Power Supply
Loop-powered 13–30 VDC or line-powered 85–250 VAC / 21–100 VDC
Output Options
4–20 mA current output plus optional SPDT relay
Repeatability
~2 mm (0.08 in) in conductive media
Response Time
Less than 1 second
Time Delay
0–60 s forward acting
Ambient Temperature
−40 °C to +70 °C
Ingress Protection
IP66 / NEMA 4X dual-compartment housing
Approvals
FM, FMc, ATEX & IECEx (Class I Div 1 / Zone 0)
Summary
Purchase Product