Specifications
- Micronics ‘Ultraflo’ U1000MKII-WM-FM Wall Mount Ultrasonic Clamp-On Flow Meter
- Up to 4” pipe size – 25-115mm OD
- Electronic transmitter – LCD with backlight
- Wall Mounted Keypad and Display Dimensions: 215mm x 125mm x 90mm
- Enclosure rating IP 68
- 5 metre transducer cables
- External Power Supply: 12V – 24V ±10% AC/DC at 7 watts per unit. Optional plug in 12V power supply
- Includes pulse output (optional 4-20mA, Modbus and M-Bus outputs can be selected)
- Modbus Communication: Optional Modbus RTU slave, RS485 serial link hardware layer. Energy, power, temperature and flow
- Mbus Communication: Optional
- Temp range: -0°C to +135°C
- Turn Down Ratio: 100:1
- Accuracy: ±1% – 3% of flow reading for velocity rate >0.3m/s (>1 ft/s)
25-115mm Micronics U1000MKII-WM-FM Wall Mount Ultrasonic Clamp-On Flow Meter
The Micronics ‘Ultraflo’ U1000MKII-WM-FM Wall Mount Ultrasonic Clamp-On Flow Meter (up to 4” pipe size – 25-115mm OD) is suitable for water and glycol applications and comes with a separate wall mounted keyboard and display. This USM is a permanent/ fixed clamp-on metering solution that utilises ultrasonic technology to measure flow rate and total flow with a volume pulse output (standard) from outside the pipe. The U1000MKII-WM-FM is a great value alternative to traditional inline heat / flow meter installation for use in industries such as energy management and building services. This clamp-on meter is easy to install as it has been factory configured and, because of this, requires minimal on-site programming and functions by simultaneously transmitting ultrasound between the clamp-on transducers in both directions. When ultrasound is emitted in the direction of flow the speed of the sound is accelerated; when it is emitted in the opposite direction the speed of the sound is decelerated. The time difference between ultrasound emissions is directly proportional to flow velocity. Using the flow velocity and the pipe’s cross-sectional area, the operator can calculate the volumetric flow.
Measurement Principle: Micronics meters use a cross-correlation transit time algorithm to provide accurate flow measurements. An ultrasonic beam of a given frequency is generated and applied to the transducer crystals. This transmission goes first from the downstream transducer to the upstream transducer as shown in the upper half of Figure 1 (below). The transmission is then made in the reverse direction, being sent from the upstream transducer to the downstream transducer as shown in the lower half of Figure 1. The speed at which the ultrasound is transmitted through the liquid is increased slightly by the velocity of the liquid through the pipe. The subsequent time difference T1-T2 is directly proportional to the liquid flow velocity.
Package contents
This wall mount ultrasonic clamp-on flow meter includes wall mounted keypad / display, adjustable transducer guide rail and all mounting hardware, banding and acoustic interface gel. A 24V DC external power supply, 3m transducer cables and volume pulse output are standard unless other selections are made below: