Roll over image to zoom in

Need help with your application? Contact us for expert advice on AMETEK Drexelbrook level instrumentation.

ABLE are AMETEK Drexelbrook’s Exclusive Representative for Sales and Service in the UK and Ireland and can assist you and your customers in the following areas:

  • Application expertise across the full AMETEK Drexelbrook product range
  • Our factory trained engineers offer after‑sales support, service and maintenance (contracts available)
  • In‑depth AMETEK Drexelbrook product training, either in person or via video call

Further to the above, ABLE can offer customised solutions based on your individual requirements. Email us now at info@247able.com

AMETEK Drexelbrook Universal V Level System

Robust RF Admittance Continuous Level Transmitter with Coating Immunity and Integral Diagnostics

ABLE Instruments are AMETEK Drexelbrook’s Exclusive Representative for Sales and Service in the UK and Ireland, including the Universal V Level System. The Universal V Level System is a continuous level transmitter leveraging RF admittance technology with patented Cote‑Shield™ coating immunity and built-in diagnostics. Designed for reliable measurement in challenging liquids, slurries or interface applications in tanks, vessels, or pipelines, it delivers stable output even in dirty or sticky fluids. Its intrinsically safe design supports custody-transfer and high-integrity systems with SIL2 (or SIL3 redundant) safety options.

Key Features:

  • Continuous RF admittance output: Provides real-time level measurement in liquids, slurries or interface zones
  • Cote‑Shield coating immunity: Unaffected by residue or deposits on sensing probes
  • Built‑in diagnostics: AutoVerify™ continuous self-test and Manual Certify™ validation
  • Flexible output options: 4–20 mA HART® loop or dual SPDT relay control outputs
  • Safety integrity available: SIL2 certified; SIL3 via redundant channel configuration
  • Density & temperature compensation: Ensures accurate readings under changing media conditions
  • Customisable probe design: Multiple probe lengths and materials for different vessel sizes and fluids
  • No moving parts: Minimises maintenance, enhances reliability in demanding environments

Have a particular project in mind? We’d welcome a call on +44 (0) 1189 169 420

Equipped with AutoVerify™ continuous diagnostics and Manual Certify™ self-test functionality, the transmitter ensures operational reliability and easy validation. Powered via 4–20 mA HART® loop or dual SPDT relays, it provides flexible output for level indication, interfaces or alarms. A choice of probe lengths and materials accommodates diverse vessel sizes and media types, while temperature and density compensation maintain accuracy in variable conditions. Ideal for oil/water interface control, storage tank level measurement, pump protection and continuous monitoring applications.

Universal V Level System Specifications:

Technology
RF Admittance with Cote‑Shield coating immunity
Output Options
4–20 mA HART®; Dual SPDT relays
Safety Certification
SIL2 (SIL3 redundant channel), IEC61508
Self‑Diagnostics
AutoVerify™; Manual Certify™
Temperature / Density Compensation
Built-in compensation algorithm
Probe Material/Length
Multiple options per application need
Operating Temperature
Typically −40 °C to +70 °C
Approvals
FM, FMc, ATEX, IECEx (Class I Div 1 / Zone 0)
Summary
Purchase Product