Roll over image to zoom in

Have a live application? Use our Flow Questionnaire and Rheonik Product Brochure to get started:

View ABLE Flow Questionnaire – Email back to [email protected]

View Rheonik Product Brochure

ABLE are Rheonik’s Exclusive Representative for Sales and Service in the UK and Ireland and can assist you and your customers in the following areas:

  • Assistance in meter sizing
  • Offer after sales support, service and re-calibration utilising our in-house expertise
  • Offer Coriolis Mass Flow Meter product training from our state-of-the-art training rig either in-person or via video call.

Further to the above, ABLE can offer custom solutions based on your individual requirements. Email us now at [email protected]

Rheonik RHE 42 Ex de Field Mount Coriolis Mass Flow Transmitter

ABLE Instruments are Rheonik’s Exclusive Representative for Sales and Service in the UK and Ireland, including the RHE 42 Ex de Field Mount Coriolis Mass Flow Transmitter. The RHE42 multifunction Coriolis mass flow transmitter from Rheonik provides reliable and accurate measurement in a wide variety of applications. Coupled with a Rheonik RHM flow sensor, the fully digital front end of the transmitter is tolerant to flow regimes not usually conducive to Coriolis meter applications (i.e., those with high pulsation/vibration/aeration). The housing is suitable for installation in a great many environments and includes a wide variety of hazardous area certifications and approvals.

The transmitter is available with or without local user display and interface. License free RHECOMPro software is downloadable from the web to allow remote communication with the transmitter for in-depth setup and configuration. Full local setup and operation is available “through glass” on units with a local display and user interface. Firmware features include, amongst others, batch control, partially filled/aerated pipe management, ultra-fast (millisecond) precision filling measurement, and net oil/API corrected volume/density reporting.

Features:

  • Measures Mass Flow, Volumetric Flow, Density and Temperature
  • Outputs 2 x Analog, 2 x Frequency/Pulse, 2 x Digital Status
  • Inputs 2 x Digital
  • PC USB / RHECom, RS 485 / Modbus RTU, Modbus TCP, Foundation Fieldbus and Profibus PA
  • Optional Backlit Color LCD
  • Installation in Hazardous Area
  • Rheonik Assurance Factor

Meters are equipped with Assurance View and Assurance Factor advanced diagnostics providing a clear insight into the operating condition of the meter and its performance. Assurance Factor can be linked to the large character colour LCD display (when fitted) to provide clear and visible signaling of measurement condition to operators and technicians nearby. The Rheonik RHE42 simultaneously measures mass flow, volumetric flow, density and temperature. Totalisers are included for forward, reverse and net accumulation of both mass and volume.

A wide range RHM flow sensors are available from ¼” to 14” line size for use with the RHE42 Coriolis Mass Flow Transmitter. With capabilities such as 20,000psi pressure ratings, exotic materials, customisable connection types/sizes and temperature ratings up to 400°C, the Rheonik Coriolis meter range covers more applications than any other Coriolis brand available on the market.

Have a particular application / project in mind? We’d welcome a call on +44 (0) 1189 169 420, or email us now at [email protected]

Why choose Rheonik Coriolis Mass Flow Meters? Unlike other Coriolis Meters, the patented Omega tube design of Rheonik Coriolis meters has solutions for operation up to 1722 bar (24,969 psi) line pressure at a precision of 0,05% and with renowned mechanical reliability. With highly accurate mass flow measurement performance and extreme capabilities, Rheonik meters are the ideal choice for many applications and quickly provide payback through improved product quality and greatly reduced maintenance. Whether used for transfer batching, process feed or control, Rheonik Coriolis Mass Flow Meters provide online precise flow and density measurement.

RHE 42 Specifications:

Enclosure Material
Powder coated aluminium
Enclosure Rating
IP65/Type 4, optional IP66-67/Type 6
Ambient Temperature
-20 to +60°C / -4 to +140°F, optional -40°C to +65°C / -40°F to 149°F
Integral version depends upon fluid temperature, refer to datasheet
Dimensions
Enclosure approx. 144 x 108 x 139 mm / 5.67 x 4.25 x 5.47 in
Weight approx. 2.3 kg / 5.1 lbs
User Interface and Configuration
Local Display Version
High contrast backlit LCD colour display and 3 x through-glass operator buttons. Configure locally or with RHECom software
Reduced display visibility below -10°C / 14°F
Blind Transmitter Version
No local controls. Configure through RHECom software package
Connection to Sensor
Integral/Compact to sensor or remote mount with 3m/10m cable
Cable Entries
2 x ½” NPT for power and I/O
Computer Connection
Via Modbus RTU to PC
Totalisers
6 x resettable forward, reverse and net totalisers for mass and volume
2 x non-resettable totalisers for mass and volume
Analog Outputs
Up to 2 x 4-20mA outputs, active or passive.
Intrinsically safe versions available
Pulse/Freq/Status Outputs
Up to 2 configurable pulse/frequency/status outputs (IEC60946).  Max. 10kHz.  Intrinsically safe versions available (open collector)
Digital Inputs
Up to 2 configurable control inputs (IEC60946).
Intrinsically safe versions available
Analog Input (optional)
1 x 4-20mA analog input (active) for two-wire pressure or density sensor
Power Supply
100-240 VAC +/- 10%  (48 to 62 Hz), 5W or 12-24 VDC +/- 10%, 4W
Digital Data Communications
HART, Modbus RTU, Ethernet (Modbus TCP/IPv4), Foundation Fieldbus H1 (FISCO), Profibus PA
Power Supply
12-24 VDC +/- 10%, 2W typical, 4W maximum
Hazardous Area Approvals
ATEX/IECEx and cCSAus
Summary
Purchase Product

Price: POA Contact 247ABLE