Have a live application? Use our Flow Questionnaire and Rheonik Product Brochure to get started:
View ABLE Flow Questionnaire – Email back to info@247able.com
ABLE are Rheonik’s Exclusive Representative for Sales and Service in the UK and Ireland and can assist you and your customers in the following areas:
- Assistance in meter sizing
- Offer after sales support, service and re-calibration utilising our in-house expertise
- Offer Coriolis Mass Flow Meter product training from our state-of-the-art training rig either in-person or via video call.
Further to the above, ABLE can offer custom solutions based on your individual requirements. Email us now at info@247able.com
Rheonik RHM 10 Medium Coriolis Mass Flow Meter < 90 kg/min
ABLE Instruments are Rheonik’s Exclusive Representative for Sales and Service in the UK and Ireland, including the RHM 10 Medium Size Coriolis Mass Flow Meter. The RHM 10, designed for demanding applications, this mass flow meter offers unparalleled precision and reliability for the measurement of liquid hydrogen.
The Rheonik RHM 10 Coriolis Mass Flow Sensor is perfect for small scale production with continuous low flow and small batch dispensing requirements. With a variety of construction styles, the RHM 10 is ideal for countless flow applications.
The real highlight is the preparation for installation in a vacuum chamber – proof of the high performance and innovative power of the product.
Features:
- Range: 0.25 kg/min up to 90 kg/min
- Pressure: up to 1384 bar (20073 psi)
- Temperature: -196°C (-321°F) up to +350°C (662°F)
- Accuracy: 0.1 % of rate
- Materials: SS 316L / SS 316Ti, Super Duplex – 1.4410, Sandvik HP160, Alloy C22 – 2.4602
- Process Connection: ½” up to 1 ½”
- Suitable for fiscal / custody transfer applications
- Available in all exotic materials
Have a particular application / project in mind? We’d welcome a call on +44 (0) 1189 169 420, or email us now at info@247able.com
Why choose Rheonik Coriolis Mass Flow Meters? Unlike other Coriolis Meters, the patented Omega tube design of Rheonik Coriolis meters has solutions for operation up to 1722 bar (24,969 psi) line pressure at a precision of 0,05% and with renowned mechanical reliability. With highly accurate mass flow measurement performance and extreme capabilities, Rheonik meters are the ideal choice for many applications and quickly provide payback through improved product quality and greatly reduced maintenance. Whether used for transfer batching, process feed or control, Rheonik Coriolis Mass Flow Meters provide online precise flow and density measurement.
RHM 10 Specifications:
Nominal Flow (Qₙₒₘ)* | 60 kg/min (132 lb/min) |
---|---|
Maximum Flow (Qₘₐₓ)* | 90 kg/min (198 lb/min) |
Typical Minimum Flow (Qₘᵢₙ)* | 0.25 kg/min (0.55 lb/min) |
Serial Tube / Single Path | Flow rates Qmax, Qnom and Qmin for “serial” sensors will be 50% of the above listed parallel/dual path version |
Operating Temperature | Fluid temperature range options cover from -196 °C to +210 °C (-320 °F to +410 °F) For integral transmitter versions please refer to transmitter datasheet |
Ambient Temperature | -50 °C to +80 °C (-60 °F to +180 °F). High temperature version for oven installation up to +210 °C (+410 °F) available |
Pressure Ratings | Up to 1379 bar / 20000 psi – dependent upon material |
Electrical Connection Sensor w/o Integral Transmitter | M20 x 1.5 standard cable entry for JM, SM terminal box versions Optional entries available : ½” NPT or M25 x 1.5 (only for SM) or ¾” NPT (only for SM) M16 x 1.5 standard cable entry for PM terminal box version Max. cable length to remote RHE transmitter 100 m/330 ft |
Sensor Enclosure Materials | Stainless steel 304 (standard), SS 316 (optional) Coated aluminium terminal box, SS 316 terminal box (optional) |
Enclosure Type | Protection class IP 66, NEMA 4 (standard), IP 66/67, NEMA 4X (optional) |
Wetted Materials | Flow tubes SS 316L, SuperDuplex or Sandvik HP160© Manifolds SS 316L, seals FKM, FFKM, FVMQ Standard flanges SS 316Ti, other connections SS 316L Additional/customer specific materials available upon request |
Process Connections | Nearly any – the Rheonik AnyPipeFit Commitment. Consult ABLE for types/sizes not listed on the Mechanical Construction pages of datasheet |
Pressure Rating Compliance | PED 2014/68/EU Article 4, Section 3 (SEP) |
Certifications / Approvals | ATEX / IECEx Approvals Zone 0, 1, 2 North American Approvals Cl. I, Div. 1, 2, Gr. A, B, C, D, Zone 0, 1, 2 OIML, MID custody transfer approval American Bureau of Shipping (ABS) Product Type Approval for use on marine vessels |
Testing / Inspection | All sensors are hydro tested, calibrated and supplied with a traceable calibration certificate. Customised calibration and testing services are available |
Project Docs / QA, Services |
Rheonik offers a full set of services for large and complex engineering projects. Typical services offered are, but not limited to: – Certificates of origin and conformity, mill certificates – Data books including WPAR, WQS, NDT, test & quality plans, functional testing, calibration procedures, customised packing, factory acceptance etc. – Painting to project specification – Start up and commissioning services on/offshore |
Options | Customisation services for machine integration. |
* At Qnom pressure drop across a parallel tube sensor will be approximately 2.2 bar (32 psi) for H₂0. Sensors can be operated at higher flow rates up to Qmax but pressure drop will be higher. Typical Minimum Flow Qmin is the recommended lowest flow rate for an accurate measurement. Sensors will measure flow rates lower than Qmin but uncertainty will increase beyond 1 % of rate.
The flow rate specifications above relate to standard pressure, parallel tube, manifold sensor versions. Models with higher pressure ratings have increased wall thickness and will have higher pressure drops.