Roll over image to zoom in

Have a live application? Use our Flow Questionnaire and Rheonik Product Brochure to get started:

View ABLE Flow Questionnaire – Email back to [email protected]

View Rheonik Product Brochure

ABLE are Rheonik’s Exclusive Representative for Sales and Service in the UK and Ireland and can assist you and your customers in the following areas:

  • Assistance in meter sizing
  • Offer after sales support, service and re-calibration utilising our in-house expertise
  • Offer Coriolis Mass Flow Meter product training from our state-of-the-art training rig either in-person or via video call.

Further to the above, ABLE can offer custom solutions based on your individual requirements. Email us now at [email protected]

Rheonik RHM 15 Medium Coriolis Mass Flow Meter < 240 kg/min

ABLE Instruments are Rheonik’s Exclusive Representative for Sales and Service in the UK and Ireland, including the RHM 15 Medium Size Coriolis Mass Flow Meter.

The RHM 15 is an all-purpose coriolis mass flow meter suitable for liquid processing plants. A wide application flow range capability allows for commonality of installation across numerous lines – a real benefit to owners and operators.

Features:

  • Range: 0 kg/min up to 240 kg/min
  • Pressure: up to 359 bar (5206 psi)
  • Temperature: -50°C (-58°F) up to +210°C (410°F)
  • Accuracy: 0.1 % of rate
  • Materials: SS 316L / SS 316Ti, Alloy C22 – 2.4602, Super Duplex – 1.4410, Tantalum – UNS R05200
  • Process Connection: ¾” up to 2″
  • Suitable for fiscal / custody transfer applications
  • Available in all exotic materials

Have a particular application / project in mind? We’d welcome a call on +44 (0) 1189 169 420, or email us now at [email protected]

Why choose Rheonik Coriolis Mass Flow Meters? Unlike other Coriolis Meters, the patented Omega tube design of Rheonik Coriolis meters has solutions for operation up to 1722 bar (24,969 psi) line pressure at a precision of 0,05% and with renowned mechanical reliability. With highly accurate mass flow measurement performance and extreme capabilities, Rheonik meters are the ideal choice for many applications and quickly provide payback through improved product quality and greatly reduced maintenance. Whether used for transfer batching, process feed or control, Rheonik Coriolis Mass Flow Meters provide online precise flow and density measurement.

RHM 15 Specifications:

Nominal Flow (Qₙₒₘ)*
150 kg/min (330.7 lb/min)​
Maximum Flow (Qₘₐₓ)*
200 kg/min (440.9 lb/min)​
Typical Minimum Flow (Qₘᵢₙ)*
2 kg/min (4.4 lb/min)
Serial Tube / Single Path
Flow rates Qmax, Qnom and Qmin for “serial” sensors will be 50% of the above listed parallel/dual path version
Operating Temperature
Fluid temperature range options cover applications from -196°C to +350°C (-320°F to +662°F).

For integral transmitter versions please refer to transmitter datasheet
Ambient Temperature
-50 °C to +80 °C (-60 °F to +180 °F) (standard), versions available for installation in vacuum chamber (-260 °C / -430 °F) or oven (up to +210 °C / +410 °F) (optional)​
Pressure Ratings
Up to 882 bar / 112792 psi – dependent upon material​
Electrical Connection Sensor w/o Integral Transmitter
M20 x 1.5 standard cable entry for JM, SM terminal box versions​

Optional entries available: ½” NPT or M25 x 1.5 (only for SM) or ¾″ NPT (only for SM)​

M16 x 1.5 standard cable entry for PM terminal box version​

Max. cable length to remote RHE transmitter 100 m/330 ft​
Sensor Enclosure Materials
Stainless steel 304 (standard), SS 316 (optional)​

Coated aluminium terminal box, SS 316 terminal box (optional)​
Enclosure Type
Protection class IP66, NEMA 4X (standard), IP66/67, NEMA 4X/6 (optional)​
Wetted Materials
Flow tubes SS 316Ti, Alloy C22, Tantalum or SuperDuplex​

Manifolds SS 316L; Seal material (manifold construction): PTFE​

Standard flanges SS 316Ti, other connections SS 316L​

Additional/customer specific materials available upon request​
Process Connections
Nearly any – the Rheonik AnyPipeFit Commitment. Consult ABLE for types/sizes not listed on the Mechanical Construction pages of datasheet
Pressure Rating Compliance
Europe – PED: Sound Engineering Practice (SEP), Module A2, Module B3.1+C2​ Canada – CRN: Canadian Registration Number
Certifications / Approvals
ATEX / IECEx Approvals for Zone 0, 1

North American Approvals Class I, Div. 1, 2, Gr. A,B,C,D, Zone 0, 1​

MID custody transfer approval (OIML R117)​

American Bureau of Shipping (ABS) Product Type Approval for use on marine vessels
Testing / Inspection
All sensors are hydro tested, calibrated and supplied with a traceable calibration certificate. Customised calibration and testing services are available
Project Docs / QA, Services
Rheonik offers a full set of services for large and complex engineering projects. Typical services offered are, but not limited to:

– Certificates of origin and conformity, mill certificates

– Data books including WPAR, WQS, NDT, test & quality plans, functional testing, calibration procedures, customised packing, factory acceptance etc.

– Painting to project specification

– Start up and commissioning services on/offshore
Options
Enclosure heating for high temperature applications​ Cleaning for oxygen service

* At Qnom pressure drop across a parallel tube sensor will be approximately 1 bar (14 psi) for H20. Sensors can be operated at higher flow rates up to Qmax but pressure drop will be higher. Typical Minimum Flow Qmin is the recommended lowest flow rate for an accurate measurement. Sensors will measure flow rates lower than Qmin but uncertainty will increase beyond 1% of rate.

The flow rate specifications above relate to standard pressure, parallel tube, manifold sensor versions. Models with higher pressure ratings have increased wall thickness and will have higher pressure drops.

Summary
Purchase Product