Roll over image to zoom in

Have a live application? Use our Flow Questionnaire and Rheonik Product Brochure to get started:

View ABLE Flow Questionnaire – Email back to [email protected]

View Rheonik Product Brochure

ABLE are Rheonik’s Exclusive Representative for Sales and Service in the UK and Ireland and can assist you and your customers in the following areas:

  • Assistance in meter sizing
  • Offer after sales support, service and re-calibration utilising our in-house expertise
  • Offer Coriolis Mass Flow Meter product training from our state-of-the-art training rig either in-person or via video call.

Further to the above, ABLE can offer custom solutions based on your individual requirements. Email us now at [email protected]

Rheonik RHM 60 Large Coriolis Mass Flow Meter < 3000 kg/min

ABLE Instruments are Rheonik’s Exclusive Representative for Sales and Service in the UK and Ireland, including the RHM 60 Large Size Coriolis Mass Flow Meter. The RHM 60 Flow Sensor is a rugged 4″ line size sensor, catering to diverse industries with a range of wetted materials, wide pressure/temperature capabilities.

Covering a broad spectrum of applications, the Rheonik RHM 60 boasts a flow range from 30 kg/min up to 3000 kg/min. This flexibility ensures it’s suitable for various fluid types, whether it’s managing high-viscosity liquids or low-density gases.

When it comes to challenging conditions, the RHM 60 stands resilient. Its pressure rating goes up to a staggering 430 bar (6236 psi), making it a reliable choice for high-pressure environments. Furthermore, its temperature range spans from -196°C (-321°F) to a remarkable +350°C (662°F), accommodating processes with extreme temperature variations.

Features:

  • Range: 30 kg/min up to 3000 kg/min
  • Pressure: up to 430 bar (6236 psi)
  • Temperature: -196°C (-321°F) up to +350°C (662°F)
  • Accuracy: 0.1 % of rate
  • Materials: SS 316L / SS 316Ti, Super Duplex – 1.4410, Alloy C22 – 2.4602
  • Process Connection: 4″ up to 4″
  • Suitable for fiscal / custody transfer applications
  • Available in all exotic materials

The Rheonik RHM 60 Coriolis Mass Flow Meter maintains an accuracy level of 0.1% of the rate, providing precision measurements crucial for quality control and decision-making in industrial processes. Offering versatility, the RHM 60 Mass Flow Flow Sensor is available in various wetted materials, including SS 316L, SS 316Ti, and Super Duplex – 1.4410. This selection of materials ensures compatibility with a wide range of fluids and enhances the sensor’s resistance to corrosive or abrasive substances. The sensor’s process connection, available in 4″ size, facilitates easy installation and integration into existing systems or new setups.

In conclusion, the RHM 60 Coriolis Mass Flow Sensor is a versatile and reliable solution, designed to meet the demands of a multitude of industries. With its impressive flow range, high-pressure and temperature tolerance, accuracy, and a variety of wetted materials, it’s the ideal choice for applications in challenging and diverse environments.

Have a particular application / project in mind? We’d welcome a call on +44 (0) 1189 169 420, or email us now at [email protected]

Why choose Rheonik Coriolis Mass Flow Meters? Unlike other Coriolis Meters, the patented Omega tube design of Rheonik Coriolis meters has solutions for operation up to 1722 bar (24,969 psi) line pressure at a precision of 0,05% and with renowned mechanical reliability. With highly accurate mass flow measurement performance and extreme capabilities, Rheonik meters are the ideal choice for many applications and quickly provide payback through improved product quality and greatly reduced maintenance. Whether used for transfer batching, process feed or control, Rheonik Coriolis Mass Flow Meters provide online precise flow and density measurement.

RHM 60 Specifications:

Nominal Flow (Qₙₒₘ)*
2500 kg/min (5512 lb/min)
Maximum Flow (Qₘₐₓ)*
3000 kg/min (6614 lb/min)
Typical Minimum Flow (Qₘᵢₙ)*
30 kg/min (66 lb/min)
Serial Tube / Single Path
Fluid temperature range options cover applications from -196°C to +350°C (-320°F to +662°F).

For integral transmitter versions please refer to transmitter datasheet
Operating Temperature
Fluid temperature range options cover applications from -196°C to +350°C (-320°F to +662°F).

For integral transmitter versions please refer to transmitter datasheet
Ambient Temperature
-50 °C to +80 °C (-60 °F to +180 °F) (standard)
Pressure Ratings
Up to 490 bar / 7107 psi – dependent upon material
Electrical Connection Sensor w/o Integral Transmitter
M20 x 1.5 standard cable entry for JM, SM terminal box versions

Optional entries available : ½” NPT or M25 x 1.5 (only for SM) or ¾” NPT (only for SM)

Max. cable length to remote RHE transmitter 100 m / 328 ft
Sensor Enclosure Materials
Stainless steel 304 (standard), SS 316 (optional)

Coated aluminium terminal box, SS 316 terminal box (optional)
Enclosure Type
Protection class IP66 / NEMA 4X with Standard Temperature Range (Option N1/NA); IP65 / NEMA 4 for Extended Temperature Ranges (Option E2 / E3 / H4)
Wetted Materials
1.4571 (SS 316Ti), 1.4410 (SuperDuplex) – standard 2.4602 (Alloy C22) – consult Factory

Additional/customer specific materials available upon request
Process Connections
Nearly any – the Rheonik AnyPipeFit Commitment. Consult ABLE for types/sizes not listed on the Mechanical Construction pages of datasheet
Pressure Rating Compliance
Europe – PED: Module A2, Module B3.1+C2

Canada – CRN: Canadian Registration Number
Certifications / Approvals
ATEX / IECEx Approvals for Zone 0, 1

North American Approvals Class I, Div. 1, 2, Gr. A,B,C,D, Zone 0, 1, 2

MID custody transfer approval (OIML R117)

American Bureau of Shipping (ABS) Product Type Approval for use on marine vessels
Testing / Inspection
All sensors are hydro tested, calibrated and supplied with a traceable calibration certificate. Customised calibration and testing services are available
Project Docs / QA, Services
Rheonik offers a full set of services for large and complex engineering projects. Typical services offered are, but not limited to:

– Certificates of origin and conformity, mill certificates

– Data books including WPAR, WQS, NDT, test & quality plans, functional testing, calibration procedures, customised packing, factory acceptance etc.

– Painting to project specification

– Start up and commissioning services on/offshore
Options
Enclosure heating for high temperature applications Cleaning for oxygen service

* At Qnom, pressure drop across a parallel tube sensor will be approximately 1-3 bar (15-44 psi)
for H20.Sensors can be operated at higher flow rates but pressure drop will be higher. Qmin is the recommended lowest flow rate. Sensors will measure flow rates lower than Qmin, but uncertainty will increase beyond 0.5 % of rate.

The flow specifications above relate to standard pressure, parallel tube, manifold sensor versions. Models with higher pressure ratings have increased wall thickness and will have higher pressure drops.

Summary
Purchase Product